Nokia 12 GSM MODULE REMOTE I/O Network Card User Manual


 
INPUT 11: Y
The Y varies according to the input pin state and it can
be:
xxxx mV if the input is in analog mode (pins 1-3)
(xxxx=value between 0-2800)
ON or OFF if the input is in digital mode (pins 4-11)
Input_Get_Change X
term123 Input Get Change
X
Response:
INPUT_GET_CHANGE Z:
INPUT X: Y
The X refers to input pin number,
X=1,2,3,4,5,6,7,8,9,10,11.
The Y refers to success state and it can be:
OK or CHECK CONFIG
Event data, when input state has changed, contains the
following information:
INPUT X: Y
The X refers to input pin number,
X=1,2,3,4,5,6,7,8,9,10,11.
The Y varies according to the input pin state and it can
be:
ON or OFF if the input is digital (4-11)
xxxx mV if the input is analog (1-3) (xxxx=value
between 0-2800)
The command
subscribes an alarm
for input pin X and the
response returns the
state of it according to
input pin configuration
Input_Change_Cancel
term123
Input_Change_Cancel X
OK Response:
INPUT_CHANGE_CANCEL X:
OK
The X refers to input pin number,
X=1,2,3,4,5,6,7,8,9,10,11,all.
The command
cancels an alarm
subscription for input
pin X
9.3.4 Reading Outputs
Use the Output_Get X commands for reading digital output states. Note that all
example control messages in this chapter use the “term123” identifier string and
the password property is set off (see Table 9).
34/49