Nokia 12 GSM MODULE REMOTE I/O Network Card User Manual


 
Table 6. Commands for the password control.
Command Type Command Comments
Changing Password
term123 passWORD
Change_PWord wordPASS
OK Response:
CHANGE_PWORD wordPASS: OK
Fail Response:
CHANGE_PWORD: FAILED
The example
changes the
password from
‘passWORD’ to
‘wordPASS’
Activating Password
Property
term123 Change_PWord
wordPASS
OK Response:
CHANGE_PWORD wordPASS: OK
Fail Response:
CHANGE_PWORD: FAILED
The example
changes an empty
password to
‘wordPASS’
Deactivating
Password Property
term123 wordPASS
Change_PWord
OK Response:
CHANGE_PWORD: OK
Fail Response:
CHANGE_PWORD: FAILED
The example
changes the
password from
‘wordPASS’ to an
empty password
Note: An indication of a password change is only sent to the phone number where
the change was requested.
9.3.2 Reading Inputs
Use the Input_Get X commands for reading inputs, that is the state or value of
a device. Note that all example control messages in this chapter use the
“term123” identifier string and the password property is set off (see Table 7)
A response depends on the pin. There are three analog inputs (1-3) and nine
digital inputs (4-11) in the Nokia 12 GSM Module M2M system interface. You
can also specify an alias for the response (see chapter 9.2).
30/49