Nokia 12 GSM MODULE REMOTE I/O Network Card User Manual


 
ERROR( Unknown Command )
Fail response, if NITZ network service is not supported
and <time> value was more than 23 hours 59 minutes
and 59 seconds:
OUTPUT PULSE OFF <time>:
ERROR( Network Time
Missing )
The X refers to output pin number,
X=1,2,3,4,5,6,7,8,9,all.
The Y refers to either ON or OFF
Command syntax for <time> parameter:
<days>d<hours>h<minutes>m<seconds>s
for example, Output_Pulse 1 On 5m30s
Value ranges for <time> parameter:
<time> If Network Indication and Time Zone (NITZ) network service is
supported, the range is from 1 second to 7 days.
If NITZ network service is not supported, the range is from 1 second to 23
hours 59 minutes and 59 seconds.
<days> If NITZ network service is supported, the range is from 1 … 7
days.
<hours> 1…23
<minutes> 1…59
<seconds> 1…59
Value examples for valid <time>:
7d, 6d23h59m59s, 45m, 59s, 4h25s, 30m45s, etc.
Value examples for invalid <time>:
7d1s Maximum time (7 days) exceeded
3m3m There cannot be two unit fields of the same
100s Maximum second and minute value is 59. Use 1m40s instead
24h Maximum hour value is 23. Use 1d instead of 24h
9.3.8 Cancelling Output Pulses
It is possible to cancel pulses before the <time> parameter defined in the pulse
control message has passed. This is done with the “Output_Pulse_Cancel
40/49