Nokia 12 GSM MODULE REMOTE I/O Network Card User Manual


 
Note: If an alias is defined, the default command will be disabled. There can be
only one effective command or alias for each function at a time. An alias must not
be equal to a default command.
Empty aliases cannot be used. If an empty alias is set, the default command will
remain effective.
Note: The alias string must be unique and the maximum length is 24 characters.
Neither commands nor aliases are case sensitive. However, the message identifier
and password are.
Table 5. List of response messages
Response Message Description
OUTPUT x: ON
Alias for output x on state, x = pin number 1-9
OUTPUT x: OFF
Alias for output x off state, x = pin number 1-9
INPUT x: *
Alias for input x voltage *, x = pin number 1-3
INPUT x: ON
Alias for input x on state, x = pin number 4-11
INPUT x: OFF
Alias for input x off state, x = pin number 4-11
* The value of the sampled voltage will be added to the end of the response. The value of the sampled voltage is
between 0 – 2800 mV, for example:
INPUT 1: 10mV
9.3 DETAILED COMMAND INFORMATION AND RESPONSES
All example commands in this chapter use the “term123” identifier string, and
the password property is set off in all of the subsequent chapters.
Note: If a command or the alias defined for it is not identified, but the identifier and
the optional password are correct, the Nokia 12 GSM Module will send an error
message as a response to the command originator, for example:
Control message: term123 passWORD ResetAll
Response: ERROR (Unknown Command)
9.3.1 Changing the Password
Use the Change_Pword command to control the password. Note that all
example commands in this chapter use the “term123” identifier string (see
Table 6).
29/49