Nokia 12 GSM MODULE REMOTE I/O Network Card User Manual


 
OUTPUT_SET ALL OFF
Set all outputs OFF
OUTPUT_INVERT ALL
Inverts all outputs
OUTPUT PULSE ALL ON
*
All outputs pulse ON *
OUTPUT_PULSE ALL
OFF *
All outputs pulse OFF *
INPUT_GET x
Return a voltage of input x, x = pin number 1-11
INPUT_GET ALL
Return states of all inputs
INPUT_GET_CHANGE x
Subscribe a voltage limit alarm of input x, x = pin number 1-
11
INPUT_GET_CHANGE
ALL
Subscribe a input state change of all inputs
INPUT CHANGE CANCEL
x
Cancel input x subscription, x = pin number 1-11
INPUT CHANGE CANCEL
ALL
Cancel all input subscriptions
CHANGE_PWORD
Change password
OUTPUT PULSE CANCEL
x
Cancel output x pulse, x = pin number 1-9
OUTPUT PULSE CANCEL
ALL
Cancel all outputs
LOCATION_GET
Get location information **
* The duration of the pulse will be added to the control message after the corresponding command. The format is the
following:
Output_Pulse 1 On <days>d<hours>h<minutes>m<seconds>s
for example Output_Pulse 1 On 5m30s
For more information about pulse commands, see Chapter 9.3.7.
** The location support needs external GPS device to be connected to the Nokia 12 GSM Module. The Nokia 12
GSM Module supports NMEA-0183 protocol.
9.2 STATUS MESSAGES
The Nokia 12 GSM Module supports the status messages listed in
Table 5. You can define an alias for each of them. The messages will be sent
as responses to device query control messages according to the current
command and device state.
28/49