Nokia 12 GSM MODULE REMOTE I/O Network Card User Manual


 
9. REMOTE I/O CONTROL SMS COMMANDS
The following chapter describes the commands and status messages available
in the Remote I/O control. Status messages are sent in response to device
status queries. You can define an alias for each of the commands and status
messages described here with Configurator.
The first part of the chapter lists commands that are sent to the Remote I/O
control as part of a control message; the second part provides a list of status
messages for which an alias can be defined.
9.1 COMMANDS
The Nokia 12 GSM Module supports the SMS commands listed in Table 4.
These commands are for controlling or monitoring purposes (to query the state
of a device attached to the Nokia 12 GSM Module). An alias can be defined for
each of the commands.
Note: If an alias is defined, the default command will be disabled. There can be
only one effective command or alias for each function at a time. An alias must not
be equal to a default command.
Empty aliases cannot be used. If an empty alias is set, the default command will
remain effective.
Note: The alias string must be unique and the maximum length is 24 characters.
Neither commands nor aliases are case sensitive. However, the message identifier
and password are.
Table 4. List of commands.
Command Description
OUTPUT_GET x
Return a state of output x, x = pin number 1-9
OUTPUT_SET x ON
Set output x ON, x = pin number 1-9
OUTPUT_SET x OFF
Set output x OFF, x = pin number 1-9
OUTPUT_INVERT x
Inverts output x, x = pin number 1-9
OUTPUT_PULSE x ON *
Output x pulse ON *, x = pin number 1-9
OUTPUT_PULSE x OFF
*
Output x pulse OFF *, x = pin number 1-9
OUTPUT_GET ALL
Return a state of all outputs
OUTPUT_SET ALL ON
Set all outputs ON
27/49