CC100 Master Bridge User’s Guide
Note that Telnet connection will be terminated automatically if the telnet client doesn’t input any command for 5
minutes; i.e. the console idle timer is 10 minutes (600 Sec).
Command Sets for Telnet Console
The following table lists all commands for Telnet console. The third column ‘Description’ explains what happens
when you run the ‘Commands’ in the first column and also explains the versatile options of the second column
Arguments’.
Some common formats for arguments are:
<mac> MAC address, format in ‘nn-nn-nn-nn-nn-nn where nn=00~FF’. As ‘00-60-64-13-03-36’.
<ip> IPv4 address, format in ‘nnn.nnn.nnn.nnn where n=0~9’. As ‘192.168.1.1’. Also applicable for
<mask>, <default gateway>
<interface> Network interface name, ‘eth0’ for LAN1/LAN2 interface, ‘hpna0’ for HCNA interface.
<fid> Flash ROM file id represented different firmware/driver, ‘n where n=0~12’,
n=0’: System bootcode (bootloader)
n=1’: System firmware (OS)
n=2’: Master HCNA driver (3110)
n=3’: 3010 EP HCNA driver
n=5’: 3110 EP HCNA driver
n=10’: 3010 EP diagnosis utility
n=11’: 3110 EP diagnosis utility
Only lowercase letter can be accepted. Typing commands followed by pressing ‘ENTER’ will execute the command.
Run any command with ‘-h’ argument will show you the usage