Nortel Networks 43W7774 Switch User Manual


 
Alteon OS Command Reference
240
The Configuration Menu 43W7774, May 2007
/cfg/l2/failovr
Layer 2 Failover Configuration
Use this menu to configure Layer 2 Failover. For more information about Layer 2 Failover, see
“High Availability” in the Alteon OS Application Guide.
[Failover Menu]
trigger - Trigger Menu
vlan - Globally turn VLAN Monitor ON/OFF
on - Globally turn Failover ON
off - Globally turn Failover OFF
cur - Display current Failover configuration
Table 6-47 Layer 2 Failover Menu Options (/cfg/l2/failovr)
Command Syntax and Usage
trigger <1-8>
Displays the Failover Trigger menu. To view menu options, see page 241.
vlan on|off
Globally turns VLAN monitor on or off. When the VLAN Monitor is on, the switch automati-
cally disables only internal ports that belong to the same VLAN as ports in the failover trigger. The
default value is off.
on
Globally turns Layer 2 failover on.
off
Globally turns Layer 2 failover off.
cur
Displays current Layer 2 failover parameters.