N-Tron 7014FX2 Switch User Manual


 
6/28/2007 page 143 of 145
KEY SPECIFICATION
Switch Properties
Number of MAC Addresses: 4,096
Aging Time: Programmable
Latency Type: 2.9 µ
s
Switching Method: Store & Forward
Physical
Height: 2.50” / 6.35 cm
Width: 7.40” / 18.8 cm
Depth: 4.10” / 10.4 cm
Weight (max): 2.10 LBS / 0.95 kg
Din-Rail mount: 35mm
Electrical
Redundant Input Voltage: 10-30 VDC
Input Current (max): 3.0 A
Inrush @ 24VDC: 12.6A/0.05ms
Input Ripple: Less than 100 mV
N-TRON Power Supply: NTPS-24-3 (3 Amp@24VDC)
Environmental
Operating Temperature: -20°C to 70°C
Storage Temperature: -40°C to 85°C
Operating Humidity: 10% to 95%
(Non Condensing)
Operating Altitude: 0 to 10,000 ft.
Shock and Vibration
(bulkhead mounting)
Shock: 200g @ 10ms
Vibration/Seismic:
50g, 5-200Hz,Triaxial
Reliability
MTBF: >1Million Hours
Connectors
10/100BaseTX: Ten (10) RJ-45 Copper Ports
100BaseFX: Two (2) SC or ST Duplex Ports
1000BaseSX/LX: Two (2) SFP LC Duplex Ports as an option
Recommended Wiring Clearance:
Front: 4" (10.16 cm)
Side: 1" (2.54 cm)
Network Media
10BaseT: >Cat3 Cable
100BaseTX: >Cat5 Cable
minimum length : 1 meter
maximum length : 100 meters
100BaseFX, 1000BaseSX:
Multimode: 50-62.5/125µm
100BaseFXE, 1000BaseLX:
Singlemode: 7-10/125µm