N-Tron 7014FX2 Switch User Manual


 
6/28/2007 page 144 of 145
100 Mb Fiber Transceiver Characteristics
Fiber Length
2km*
15km**
40km**
80km**
TX Power Min/Max
-19dBm/-14dBm
-15dBm/-7dBm
-5dBm/0dBm
-5dBm/0dBm
RX Sensitivity Max
-32dBm
-29dBm
-34dBm
-34dBm
Wavelength Min/Max
1310nm
1310dm
1310dm
1550nm
* Multimode Fiber Optic Cable
** Singlemode Fiber Optic Cable
Gigabit Fiber Transceiver (SFP) Characteristics
Fiber Length
550m* with
50/125 µm
10km** 40km** 70km**
TX Power Min/Max
-9.5dBm/-4dBm -9.5dBm/-3.5dBm -2dBm/3dBm 0dBm/5dBm
RX Sensitivity Max
-17dBm -20dBm -22dBm -24dBm
Wavelength
850nm 1310nm 1310nm 1550nm
Assumed Fiber Loss
-0.5 dB/km -0.35 dB/km -0.25 dB/km
Laser Type
VCSEL FP DFB DFB
*SX Fiber Optic Cable
** LX Fiber Optic Cable
Regulatory Approvals:
Safety: UL Listed per ANSI/ISA-12.12.01-2000 (US and Canada)
This apparatus is suitable for use in Class I, Div 2, Groups A, B, C, and D, T4
EMI: EN61000-6-4, EN55011 – Class A
FCC Title 47, Part 15, Subpart B - Class A
ICES-003 – Class A
EMS: EN61000-6-2
EN61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-4 (EFT)
EN61000-4-5 (Surge)
EN61000-4-6 (Conducted Disturbances)