3.2 Confirming the I/O Allocation and Root No.
3.2.2 Confirming Root No.
If multiple Computer Communication Units have been installed, they are labeled “Root
No. 1”, “Root No. 2”, and “Root No. 3” in sequential order, starting from the unit closest
to the CPU unit.
Root numbersare not useddirectly in thehandling of theComputer Communication Unit,
but if a Multiwire Link Unit is being used at the same time, these numbers are
sometimes specified on the Multiwire Link Unit side.
Example:
When two Multiwire Link Units and one Computer
Communication Unit are being installed
Multiwire Link Unit
(MEWNETW mode)
Computer Communication Unit
Root No. 1
Root No. 2
Root No. 3
If a Multiwire Link Unit set to the MEWNETW mode has also been
installed, the root numbers are set so that the Multiwire Link Unit is also
included.