ENGLISH-55
Care and maintenance
54-ENGLISH
Replacing the lamp unit
Warning
When replacing the lamp, allow it
to cool for at least one hour
before handling it.
BThe lamp cover gets very hot,
and contact with it can cause
burns.
Notes on replacing the lamp
unit
BThe light generating lamp is
made of glass, so dropping it or
allowing it to hit hard objects may
cause it to burst. Be careful when
handling the lamp.
BAfter having removed the old
lamp, carelessly discarding it can
cause the lamp to burst. Dispose
of the lamp with the same care
that would be taken with a
fluorescent light.
BA Phillips screwdriver is
necessary for removing the lamp
unit. Make sure that your hands
are not slippery when using the
screwdriver.
Lamp unit replacement
period
The lamp is a consumable product.
Even when the full life of the bulb
has not been exhausted, the
brightness of the light will gradually
decline. Therefore periodic
replacement of the lamp is
necessary.
The intended lamp replacement
interval is 2 000 hours, but it is
possible that the lamp may need to
be replaced earlier due to variables
such as a particular lamp’s
characteristics, usage conditions
and the installation environment.
Early preparation for lamp
replacement is encouraged.
A lamp that has exceeded 2 000
hours of use has a much greater
chance of exploding. In order to
prevent the lamp from exploding,
the lamp will be automatically shut
off when 2 000 hours of use have
been reached.
NOTE:
BThe projector is not supplied
with a replacement lamp unit.
Please ask your dealer for
details. Lamp unit product
no.: ET-LA735
CAUTION:
BDo not use any lamp unit other
than the one with the product
number indicated above.
NOTE:
BThe usage hours explained
above are for use when the
HIGH setting has been
selected for LAMP POWER in
the OPTION menu. If the
“LOW” setting is selected, the
brightness of the lamp will be
less and life of the lamp can be
extended.
BWhile 2 000 hours is the
intended replacement interval,
it is not a period of time
covered by warranty.
NOTE:
BPlace the projector on top of a
soft cloth so that it will not
become scratched.
NOTE:
BBe sure to install the air filter
cover before using the
projector. If the projector is
used without the air filter cover
installed, dust and other
foreign particles will be drawn
into the projector, and
malfunctions will result.
BIf the dust cannot be removed
by cleaning, it is time to
replace the air filter. Please
consult your dealer.
Furthermore, if the lamp unit is
being replaced, replace the air
filter at this time also.
Cleaning and replacing the air filter
If the air filter becomes clogged with dust, the internal temperature of the
projector will rise, the TEMP indicator will flash and the projector power will
turn off. The air filter should be cleaned after every 100 hours of use.
#Turn off the MAIN POWER
switch and disconnect the
mains lead plug from the mains
socket.
Turn off the MAIN POWER switch
according to the procedure given
in “Turning off the power” on
page 25 before disconnecting the
plug from the mains socket.
$Gently turn the projector
upside down.
%Remove the air filter.
Put your fingernails under the air
filter and pull the air filter out of
the projector.
&Clean the air filter.
Soak the air filter in water and
wash out dirt by hand.
'Dry the air filter and install it to
the projecter.
Air filter
NOTE:
BDo not use detergent.
BBe careful not to separate the
air filter cover from the frame
when washing the air filter.