Panasonic TQBJ0299-3 Projector User Manual


 
PROJECTOR SETUP menu
ENGLISH - 29
Settings
You can select a lamp lighting pattern for using environment.
Press I H to cycle through options, and the ENTER button.
If using the projector for a continuous period of 24 hours or
more, this setting can be used to automatically switch the
lamps that are turned on in order to reduce the lamp
deterioration that can occur as a result of continuous use.
(Not available for PT-D5000)
The luminance of the projection lamp can be changed
depending on user’s needs or the viewing conditions.
You can select the electrical consumption while in standby
mode.
This sets the communication parameters at the serial
terminals.
You can customise the REMOTE 2 IN terminal function.
DEFAULT The pin assignment of the REMOTE 2 IN
terminal is used as the projector default
setting.
USER For changing an optional input module or
customising the pin assignments.
LAMP SELECT
DUAL All lamps will light.
SINGLE
Selects a lamp with shorter duration of
use.
LAMP1 Selects the Lamp unit 1.
LAMP2 Selects the Lamp unit 2.
NOTE:
If, in the SINGLE, LAMP1 or LAMP2 mode, one lamp remains
off or the currently active lamp exceeds 2 000
*1
hours of
cumulative operating time (when HIGH is selected as the
LAMP POWER setting
*2
), the other lamp will light. If, in the
DUAL mode, one lamp remains off or the currently active lamp
exceeds 2 000
*1
hours of cumulative operating time (when
HIGH is selected as the LAMP POWER setting
*2
), the other
lamp alone will light. However, if both lamps remain off or the
2 000
*1
hours of cumulative operating time (when HIGH is
selected as the LAMP POWER setting
*2
) are exceeded, the
projector will enter the standby mode.
The colours of the items indicate the status.
Green: Current setting
Yellow: Current setting (when a lamp fails or fails to light)
Red: Lamp that has failed to light
White: Any other status.
If the projector is repeatedly used for short periods of time, the
lamps will need to be replaced more frequently.
*1. 3 000 hours for PT-D5000 only.
*2. Not available for PT-D5000.
LAMP RELAY
OFF Deactive
00:00 - 23:00 1 hour interval from 00:00 to 23:00
NOTE:
Only when DUAL or SINGLE is selected in LAMP SELECT,
LAMP RELAY is available. If LAMP1 or LAMP2 is selected,
LAMP RELAY function is not available.
LAMP SELECT
setting
Repeated operation
SINGLE
LAMP1 and LAMP2 light alternately by the
set time, and the shorter duration of use
lamp will light first.
DUAL
After both lamps light for the set time, only
one lamp is turned off for 2 hours, then for
only the other lamp for next 2 hours. The
longer duration of use lamp will be turned off
first.
LAMP POWER
HIGH Set when high brightness is necessary.
LOW
Set when high brightness is not
necessary.
NOTE:
When set to LOW, it is possible to reduce power consumption,
reduce operating noise and extend lamp service life.
STANDBY MODE
NOTE:
•With ECO setting, NETWORK function, RS-232C output and
some of RS-232C commands are not available. When switch
on the projector, projection will start about 10 seconds late.
RS-232C
(IN) BAUDRATE Select 9600, 19200 or 38400.
(IN) PARITY Select NONE, EVEN or ODD.
(OUT) BAUDRATE Select 9600, 19200 or 38400.
(OUT) PARITY Select NONE, EVEN or ODD.
RESPONSE(ID ALL) Select ON or OFF.
GROUP Select A to Z.
RESPONSE(ID GROUP) Select ON or OFF.
REMOTE2 MODE
PIN1 GND
PIN2 POWER H NONE
PIN3 - PIN7
RGB1 H RGB2 H VIDEO H S-VIDEO H DVI-
D H BALLAST VERSION H REWIND ALL
FILTER H NONE
PIN8 SHUTTER H NONE
PIN9 ENABLE H DISABLE