Paradyne 3800 Network Card User Manual


 
COMSPHERE 3800 Series Modems
9-14 September 1998 3810-A2-GB30-30
Table 9-1
(7 of 7)
DTE Interface Configuration Options
CT111_Rate Cntl: Disable
Nxt Disable Fallback1 Fallback2
CT111 Rate Control. Allows the DTE to control modem rate via Pin 23 of the EIA-232-D interface. This option determines
the effect of the DTE Rate control signal. CT111 is also known as CH on the EIA-232-D interface.
Disable Disregards CT111 Rate Control.
Fallback1 Forces the modem to decrease its configured data rate to the next lower data rate when CT111 is Off. Valid
only for V.32bis, or, if installed, V.29 and V.33 modulations. Modem will only fall back within the same modulation
scheme. When CT111 turns ON, the modem returns to its previous data rate.
Fallback2 Forces the modem to decrease two data rates while remaining in the same modulation scheme. When
CT111 turns ON, the modem returns to its previous data rate.
NOTE: This configuration option is only valid in Async Direct mode and Synchronous mode. For proper operation,
disable the V32bis Autorate and V32bis Automode configuration options.
The factory default is Disable.
AT command is S-register S61 = n, where n is 0 for Disable, 1 for Fallback1, and 2 for Fallback2.
DTE Rate=VF: Disable
End Disable Enable
DTE Rate = VF Rate. Forces the data rate of the connection between the DTE (computer) and the modem to be the
same as the VF (telephone line) rate.
Disable The DTE rate is the value of the Async DTE Rate configuration option.
Enable The DTE rate is identical with the VF rate.
The factory default is Disable.