Paradyne 8546 Network Card User Manual


 
MCC Card Configuration
5-5
8000-A2-GB20-20
November 1997
MCC Configuration Ports Screens
(Reserved for Future Use)
NOTE:
There are no configurable ports on the MCC at this time.
MCC Configuration Interfaces Screens
Use the system information submenu of the Interfaces screens to configure basic
interface information.
" Procedure
To configure general interfaces, IP networks, and control interfaces:
1. Follow this menu sequence:
Configuration
Interfaces
(A-C)
2. The Interfaces menu appears. Enter the desired value on each selected
screen and field as shown in Table 5-2 and press Return.
Table 5-2. Interfaces Menu Options (1 of 2)
General (Interfaces) A-C-A
Gives the user the ability to configure basic information about a given interface.
Interface Name – s1b = backplane that connects all the cards, e1a = Ethernet port.
Type – Static.
Protocol – Type of protocol for an interface.
Port List – Name of the port associated with this interface.
MTU (max) (Maximum Transmission Unit) – 64–64000 (Default = 1500). For the
Model 8540, the MTU (max) is 1500, with the range being 61–1500.
NOTE: The above MTU values are the only values you may enter. Do not change
the MTU of s1b from the default of 1500. Make certain that if you change
from the default value, the numbers are appropriate to your network. Do a
card reset or reset the interface.