Patton electronic 1082 Network Card User Manual


 
10
Note
When setting the 1082 for SNMP Management, the DTE rate
switches (S1-1,S1-2, and S2-1) must be also set to the ON posi-
tion. Therefore, to set a 1082 unit SNMP Mangagement mode, the
following switches have to be at the ON position, S1-1, S1-2, S2-1.
Switches S1-1 and S1-2: Data Rate
Use switches S1-1 and S1-2 to configure the asynchronous or synchro-
nous data rate of the Model 1082 and Model 1082/144. Each setting rep-
resents one synchronous data rate and one asynchronous data rate.
Note
The Model 1082 can also operate at the 19.2 kbps synchronous
rate, and the Model 1092/144 can also operate at the 144 kbps
synchronous rate. To operate at these rates, set switches S1-1
and S1-2 both to the OFF position and Switch S2-1 to the ON
position (see section , “Configuring DIP switch S2” on page 122
for a description of Switch S2-1).
If the S2-1 switch is positioned in the OFF position, the 128 kbps
sync data rate/0–38.4 kbps async data rate option is selected.
Switch S1-3: Data Set Ready during Line Loopback Test
Use Switch S1-3 to control the behavior of the DSR signal at the EIA
interface during the line loopback test.
S1-1 S1-2 Sync Data Rate Async. Data Rate
On On 32 kbps Reserved
Off On 56 kbps Reserved
On Off 64 kbps Reserved
Off Off 128 kbps (see note) 0–38.4 kbps
Off Off 144 kbps or 19.2 kbps (see note) Reserved
S1-3 Setting
On DSR is on during local line loop
Off DSR is off during local line loop