2 • Hardware installation Model 3125 RAS Getting Started Guide
30 Model 3125 installation
7. Verify that the module is properly seated, then secure it to the chassis using the captive fasteners located
adjacent to the injection/ejection handles (see figure 11).
Figure 11. Securing the captive fasteners
Installing the 3125RC Resource Card
1. If there is not a slot filler panel installed, go to step 2. Otherwise, remove the two screws (located at the top
of the filler panel and at the bottom) that secure the panel to the card cage.
2. Remove the 3125RC Resource Card from its anti-static bag.
3. Press on the red tab on each injection/ejection handle to release the handle (see figure 7 on page 28).
4. Locate the slot where the 3125RC will be installed. Insert the 3125RC so it enters the corresponding top
and bottom slot guides as shown in figure 8 on page 28.
5. Carefully slide the 3125RC into the chassis until it engages the mid-plane (see figure 9 on page 29), when
that happens, pivot the injection/ejection handles into locked position (see figure 10 on page 29).
6. Verify that the module is properly seated, then secure it to the chassis using the captive fasteners located
adjacent to the injection/ejection handles (see figure 11).