Configuring the RAS with a Web browser 53
Model 3125 RAS Getting Started Guide 3 • Configuring the RAS for operation
Note The information entered into the Interregister Signaling section must
match the information the telco provided. If the information entered
is not the same, the RAS may not answer calls. In some installations,
the phone company will send a special tone to alert that it is done
sending the Calling Number. In this case, the value in the Total Dig-
its box does not have to match the telephone company’s exactly.
Channel assignment
This section describes configuring the RAS so it will know which channels are active. Do the following:
1. Select
T1/E1 Link on the Configuration Menu. The T1/E1 Link Activity window appears (see figure 32 on
page 49).
2. Click on
Channel Assignment. The WAN Circuit Channel Assignment window appears (see figure 37).
Figure 37. WAN Circuit Channel Assignment window
3. Click on the Dialin button located under Set all channels to:.
4. Click on
Submit Query.
Configuring line settings and signaling for T1
1. Select T1/E1 Link on the Configuration Menu. The T1/E1 Link Activity window appears (see figure 32 on
page 49).
2.
Link: 1 corresponds to Line 1 on the RAS. This is the primary link for dial-in callers. Under Link 1, Click
on
Configuration then Modify. The Line Interface Settings section of the WAN Circuit Configuration
window appears (see figure 33 on page 49).
Configuring the line settings
1. Click on the Line Type pop-up menu (see figure 33 on page 49) and choose from the following options:
dsx1ESF Extended SuperFrame DS1