Patton electronic 3088 Network Card User Manual


 
27
Follow the instructions below to activate RocketLink Plug ‘n’ Play
between CO (Model 3096RC and CP (Model 3088) units:
Set the Model 3096RC (CO) to either Internal or External clocking
mode as defined by the application.
Set the Model 3088 (CP) to “RocketLink Plug-and-Play CP” by setting
S1 and S2 DIP switches in the ON position as described in figure 4.
Figure 4. Typical RocketLink Plug ‘n’ Play Application
When the CO and CP units connect over DSL, the CP will enter a pre-
defined default configuration (Receive Recovered Clocking). During the
negotiation process between the units, the CO unit will configure the
DTE rate/line rate on the CP unit as defined by the settings of the CO
unit. When additional bandwidth is required, only the configuration of the
CO unit should be changed. This feature gives ISPs, LECs and PTTs the
ability to provision bandwidth on an as needed basis to customers.
3096RC
(CO)
3088
(CP)
DIP Switches all in ON position
DIP Switches or NMS configured
according to specific application
requirements
DSL Span