8 C698M-A (6/04)
SUPPORTED COMMUNICATION TYPES
Data Encoding Data Format Baud Rate Data Bits Parity Stop Bits*
Asynchronous NRZ ASCII 19200 8 None 1
SNA/SDLC NRZ EBCDIC 9600 7 Odd 2
SNA/SDLC NRZI 4800 Even
2400
1200
600
300
* Stop bits are selected automatically.
NOTE: Programming is done in the DX2000 system setup.
SETTING UP THE SYSTEM
You need to do the following to set up your system:
1. Rack mount the data hub(s) (if applicable).
2. Connect the devices as described in the Installation section.
3. Power up the data hub(s) (as described in the
Connecting Power to the Data Hub
).
4. Program the DX2000 as described in the
Programming the DX2000 DVR for Use with a Data
Hub
section.
5. Turn power on to units as described in the
Powering Up and System Operational Status
section.