Logical Drive and LUN Numbering Strategy
3
Logical Drive and LUN Numbering Strategy
A suggested strategy is to create a logical drive for each blade server. Each
logical drive has its own LUN. The LUN is 0 so the blade server can boot from it.
This strategy is followed throughout this document. You are free to use a different
strategy that better meets your needs.
Prerequisites
The Modular Server-to-VTrak connection requires:
• Modular Server, setup and running with a network connection
• VTrak, setup and running with a network connection
• Networked PC workstation running Windows OS, to access Module Server
Control and WebPAM PROe
• SAS cable with SFF-8088 Mini-SAS external connectors. The cable must be
long enough to reach from your Modular Server to your VTrak.
• RJ11-to-DB9 serial data cable supplied with the VTrak. This cable is required
to verify the VTrak’s IP address
Blade Server Logical Drive LUN
Slot 1 LD1 LUN0
Slot 2 LD2 LUN0
Slot 3 LD3 LUN0
Slot 4 LD4 LUN0
Slot 5 LD5 LUN0
Slot 6 LD6 LUN0