Quatech DSE-410D Network Card User Manual


 
RS-422 Connections
In the RS-422 mode, TXD lines are outputs and RXD lines are inputs. Connect the
TXDB(+) line to the RXDB(+) line of your device, and the TXDA(-) line to the
RXDA(-) line of your device.
If Flow Control is set for RTS/CTS, connect the RTSB(+) line to the CTSB(+) line of
your device and RTSA(-) to CTSA(-) of your device. Connect from CTSB(+) to
RTSB(+) of your device and from CTSA(-) to RTSB(+) of your device.
If connecting to Receive Only RS-422 devices, connect from TXDB(+) and TXDA(-)
to the receive pairs on all your devices.
Ground is signal ground and provides a common mode reference for the RS-422
Receiver and Transmitters.
The RS-422 mode can be used for full duplex 4-wire RS-485 operation provided that
the DSE-410D is acting as a sole master connecting to all the slave devices, and all
slave devices share the Receive signal lines to the master. Set Flow Control for none,
and omit connections to RTS/CTS line pairs.
12 DSE-410D Owner’s Manual Document Number: 940-0186-100
Quatech, Inc. - 5675 Hudson Industrial Parkway, Hudson, OH 44236 – 330.655.9000
http://www.quatech.com