59
•
Highlight the first point in the [Break condition] list box.
•
Click the [Edit...] button. The [Break condition 1] dialog box is displayed.
•
Clear the [Don't care] check box in the [Address] page.
•
Select the [Only program fetched address after] radio button and enter
H'108C
as the value in
the [Address] edit box.
Figure 3.42 [condition] Page ([Break condition 1] Dialog Box)
Note: The items that can be set in this window differ according to the product. For the
settings for each product, refer to the on-line help.
•
Click the [OK] button.
•
The [Break] dialog box is displayed. Check the first point display in the [Break condition] list
box is changed from Empty to Enable.