SATO CT410 Printer User Manual


 
Continuous Forms Printing
Command Structure None
The printer locates the end of an adhesive label by sensing the
backing between labels or through the use of an eye-mark (black
rectangle on the reverse side of the backing). It locates the end of a
tag from a notch, eye-mark, or a hole between tags. Both sensors
should be disabled when printing continuous forms. See
Configuration Commands at the end of this section for information on
using the <ESC>IG Sensor Select command. To change the default
setting to Continuous Forms Printing, use the <ESC>PG Printer
Setting command.
If you will be using continuous labels or tags, the printer must be told
to stop feeding in another manner. The length is determined by the
position of the last printed image on the label or tag. The printer will
stop feeding when this last field is finished printing. The length may
be increased with printed spaces (20 hexadecimal) if necessary.
There is no command code to control label length.
Section 4. Programming Reference
Page 4-289001069A SATOCTSeriesPrinters