SATO GL 4xxe All in One Printer User Manual


 
11
Admin User Menu Items (GL4xxe)
These menu items are visible only when the
A
dmin User option is set to Enable in the Advanced menu.
(See the GL408/412e Operator’s Manual.)
IMPORTANT
Admin User menu items should only be used by authorized personnel.
Error Handling
This menu item selects the error handling mode for RFID failures. The default is Overstrike.
In Overstrike mode, each failed label prints with the Overstrike pattern and the form retries on a new
label until the Label Retry count is exhausted. Whether or not an error message will display (or the failed
label will reprint) depends upon the Max Retry Error setting.
In None mode, no specific action is taken when a tag fails to be programmed.
In Stop mode, when a tag fails to be programmed, the printer will halt and display the error message
RFID Error: Check Media.” The label is discarded and reprinting of the label (if desired) must be
initiated from the host. When the error is cleared, the label with the failed tag moves forward until the
next label is in position to be printed.
Max Retry Error
Enables or disables Max Retry Error. If it is set to Disable, errors are not declared and the print content
for the current label is discarded. The default is Enable.
Clear Tag Stat
This menu item clears the Tag Write Cnt, Failed Tag Cnt, Tag Void Cnt, and Tag Read Cnt menu items.
I
n
t
ro
d
uc
ti
on
t
o
th
e
RFID
con
fi
gura
ti
on op
ti
ons