SATO GL 4xxe All in One Printer User Manual


 
26
[Return Status Example 1]
When [8000 0000 4000 0001] is saved in an EPC-compatible tag.
02 Start code
38 30 30 30 30 30 30 30 34 30 30 30 30 30 30 31
03 End code
* In actuality, all data is continuous.
* Data is displayed in hexadecimal code.
[Return Status Example 2]
When there is no EPC-compatible tag .
02 Start code, error flag
45 50 43 5F 54 61 67 5F 45 72 72 Returning [EPC_Tag_Err] in ASCII char
03 End code
* In actuality, all data is continuous.
* Data is displayed in hexadecimal code.
[Notes]
1. This command cannot be used in combination with other commands.
2. This command is to be processed after the completion of print, not during the print.
3. It takes a few seconds after the command is sent until all return statuses are returned to the host
computer. If the port is closed before all return statuses are returned to the host, the tag data will not
be correctly returned and the data other than return status format is returned. You must then sort the
data before operating.