16
Scan Start Pos
Determines where on the label the RFID calibration will begin. By default, the calibration procedure will
start at the beginning of the label (0.0 mm). To speed this up change this value to force the calibration to
begin after the beginning of the label.
Scan Length
Determines how much of the label will be scanned during the RFID calibration procedure. The default is
76mm.
Cal Min Powe
r
Determines the minimum power level that the calibration procedure will use when attempting to find
the ideal power level. To speed this up, increase the value to exclude the lower power levels. The
default is 1.
Cal Max Power
Determines the maximum power level that the calibration procedure will use when attempting to find
the ideal power level. To speed this up, decrease this value to exclude the higher power levels. The
default is 20.
Introduction to the RFID configuration options