SATO 410 Printer User Manual


 
Printer Output
Special Notes 1. The value specified for Print Quantity should be equal to the
number of different sequential values desired multiplied by the
number of repeats specified.
Example:
To print 2 sets each of the numbers 1001-1025 on separate
labels, we need 50 total labels. The commands would be as
follows:
<ESC>A
<ESC>H0100<ESC>V0100<ESC>F0002+001<ESC>XM1001
<ESC>Q50
<ESC>Z
2. It is necessary to specify the print position for each sequential field
on a label.
3. Up to eight different sequential fields can be specified per label.
4. This command ignores alpha characters in the sequential number
field for decimal counting after the last hexidecimal (F) character.
5. This command can not be used with the following commands:
Copy Image
Reverse Image
Line Feed
6. The “a” field can be omitted. If it is omitted, the sequential
numbering will be a decimal count.
Section 4. Programming Reference
SATOCT SeriesPrinters9001069A Page4-69