Device Management
Device Information
The Device Management page opens with the top level (parent) KVM switch selected in the Sidebar and
Device Information selected on the menu bar.
General
The General section of the Device Information page displays the name of the selected device, its
firmware version, and information about its network configuration.
Note: The AP GUI version presents the same information as the Browser version. Scroll
through the list to see additional entries.
Environment
The lower panel displays the device's environment information.
Operating Mode
Use the Operating Mode page to set working parameters.
Force all to grayscale: Enable to change the remote displays of all devices connected to the KVM
switch to grayscale. This can speed up I/O transfer in low bandwidth situations.
Enable Device List: Enable for the switch to appear in the Server List of WinClient or Java Client
AP. See “Windows Client AP Login” on page 20, and “Java Client AP Login” on page 21. The
switch can still be connected, but its name will not appear in the Server List if the option is not
enabled.
Item Description
Power Supply
Detection
Power Supply 1 and Power Supply 2 icons display in gray when there is no power to the power
supply and in blue when power is present.
When enabled (there is a check in the checkbox), if there is only one source of power, a constant
warning beeps. A message displays asking for confirmation that having one power source is
intentional.
If one source of power is intended, to stop the beeping:
• Uncheck the checkbox to disable the function permanently.
• Confirm your intention in the dialog box to disable the warning temporarily. The warning
function will be back on after the next system reset.
The default for this function is enabled.
Fan Warning
Message
Place a check in the checkbox to enable a fan warning message. If enabled, when any fan stops
spinning the system records the event in the system log. If it is not enabled, the event will not be
recorded. The default for this function is enabled.
Note: The warning does not mean that the fan has failed, since the fans stop when the
temperature drops below the device's lower temperature setting.
Fan Speed Displays fan speeds. See “Fan Location and Speed Information” on page 109.
Temperature
Warning
Message
Place a check in the checkbox to enable a temperature warning message. If enabled, when the
device's temperature drops below the Low threshold setting, or exceeds the High threshold
setting, the system records the event in the system log. If it is not enabled, the event will not be
recorded. The default is enabled.
Temperature Displays temperature readings from the switch's built-in sensors in Celsius or Fahrenheit. See
“Temperature Sensor Location and Information” on page 109.