Sharp FO-475TH Fax Machine User Manual


 
UX-258TH
FO-475TH
1 Max OGM record time 15s 60s 0
2 Reserved 0
3 Two way record function Disable Enable 0
4 Toll saver Disable Enable 0 OPTION
5 Reserved 0
6 Reserved 0
7 BOX selection to record ICM 2 digits DTMF 1digit DTMF 0
8 Transfer did recall Disable Enable 0
1 AGC maximum gain (line) Binary input 1
2 (10 ~ 25 dBm ) No. = 8 4 2 1 1
3 1 2 3 4 0
4 1 1 0 1 (23 dB) 1
5 AGC maximum gain (Mic) Binary input 0
6 (10 ~ 25 dBm ) No. = 8 4 2 1 0
7 5 6 7 8 1
8 0 0 1 0 (12 dB) 0
1 AGC eref access code (line) Binary input 0
2 (-0 ~ -30 dBm with 2 dBm step) No. = 8 4 2 1 1
3 1 2 3 4 1
4 0 1 1 1 (-14 dB) 1
5 AGC eref access code (Mic) Binary input 1
6 (-0 ~ -30 dBm with 2 dBm step) No. = 8 4 2 1 0
7 5 6 7 8 0
8 1 0 0 1 (-18 dB) 1
1 AGC again adaptation threshold (line) Binary input 1
2 (-40 ~ -70 dBm with 2 dBm step) No. = 8 4 2 1 1
3 1 2 3 4 1
4 1 1 1 1 (-70 dB) 1
5 AGC again adaptation threshold (Mic) Binary input 0
6 (-40 ~ -70 dBm with 2 dBm step) No. = 8 4 2 1 1
7 5 6 7 8 0
8 0 1 0 1 (-50 dB) 1
AGC slew rate (line) Slow Normal Little fast Fast
1 No. 1 0 0 1 1 0
2 No. 2 0 1 0 1 1
AGC slew rate (Mic) Slow Normal Little fast Fast
3 No. 3 0 0 1 1 1
4 No. 4 0 1 0 1 1
5 FAX BOX function Disable Enable 0 OPTION
6 Frequency of voice detection after 800 Hz ~ 1400 Hz 800 Hz ~ 1200 Hz 0
REMINDER dialing
Voice detection time after REMINDER dialing
100ms 200ms 300ms 400ms
7 No. 7 0 0 1 1 0
8 No. 8 0 1 0 1 0
1 Reserved 0
2 Reserved 0
3 Sender’s phone number setting Cannot change Change allowed 0
4 Reserved 0
5 Reserved 0
6 Reserved 0
Ringer volume Off Low Middle High OPTION
7 No. 7 0 0 1 1 1
8 No. 8 0 1 0 1 0
SW
l
I3
SW
l
I4
SW
l
I5
SW
l
I6
SW
l
J1
SW
NO.
DATA
NO.
ITEM
Switch setting and function
1
0
Remarks
Initial
setting
2 – 10
SW
l
I7