Sharp PG-B10S Projector User Manual


 
-61
Appendix
1
2
Replacing the Air Filter
Tab
This projector is equipped with air fil-
ters to ensure the optimal operating
condition of the projector.
The air filters should be cleaned every
100 hours of use. Clean the filters more
often when the projector is used in a
dusty or smoky location.
Ask your nearest Sharp Authorized Pro-
jector Dealer or Service Center to ex-
change the filter (PFILDA010WJZZ)
when it is no longer possible to clean.
Cleaning and Replacing
the Air Filter
1 Press on the projector
or
STANDBY
on the remote control to
put the projector into the
standby mode.
Wait until the cooling fan stops.
2 Disconnect the power cord.
Unplug the power cord from the AC
socket.
3 Remove the filter cover.
Turn the projector over. Loosen the user
service screw (1) that secures the fil-
ter cover. Pressing the tab, remove the
filter cover (2).
STANDBY button
Air filter (not removable)
User service screw
Air filter (removable)
""
""
" Bottom view
""
""
" Front view
STANDBY
button
STANDBY
AC socket