Sharp PG-B10S Projector User Manual


 
-66
Lamp
unit
BQC-PGB10S//1
Removing and Installing
the Lamp Unit
Info
Be sure to remove the lamp unit using the
handle. Be sure not to touch the glass sur-
face of the lamp unit or the inside of the
projector.
To avoid injury to yourself and damage to
the lamp, be sure to carefully follow the
steps below.
Do not loosen other screws except for the
lamp unit cover and lamp unit.
Please refer to the installation manual in-
cluded with the lamp unit.
1 Press on the projector
or
STANDBY
on the remote control to
put the projector into the
standby mode.
Wait until the cooling fan stops.
Warning!
Do not remove the lamp unit from the
projector right after use. The lamp will
be very hot and may cause burn or
injury.
2 Disconnect the power cord.
Unplug the power cord from the AC
socket.
Leave the lamp until it has fully cooled
down (about 1 hour).
3 Change the air filter.
Change the air filter whenever you in-
stall the lamp unit (see pages 61 and
62).
4 Remove the lamp unit cover.
Turn the projector over. Loosen the user
service screw (1) that secures the lamp
unit cover. Pressing the tab, remove the
lamp unit cover (2).
1
2
AC socket
Tab
User
service screw
STANDBY button
STANDBY
button
STANDBY
Regarding the Lamp