Table 1. Default Symbologies of the SDSC 3E
Symbology
Scanner
Default
Default
Length
Length after
Symbology
Selector
UPC/EAN/JAN
UPC-A Enabled N/A N/A
UPC-E Enabled N/A N/A
UPC-E1 Disabled N/A N/A
EAN-8 Enabled N/A N/A
EAN-13 Enabled N/A N/A
Code 128 (USS-128 & UCC/EAN 128) Enabled Any Any
Code 39*
Code 39 Enabled 2 to 23 2 to 55
Trioptic Code 39 Enabled 2 to 23 2 to 55
Code 39 Full ASCII Disabled 2 to 23 2 to 55
Code 93 Disabled 2 to 38 2 to 55
Interleaved 2 of 5* Enabled 14 Only 2 to 55
Discrete 2 of 5* Disabled 12 Only 2 to 55
Codabar Disabled 5 to 55 2 to 55
MSI Plessey* Disabled 1 to 30 2 to 55
Code 11 Disabled 2 to 41 2 to 41
Webcode Disabled 2 to 55 2 to 55
WARNING! Setting the length to “Any” may lead to inaccurate
decodes of these symbologies!
38 | APPENDIX C: ENABLING OR DISABLING SYMBOLOGIES