Sony SDX-1100V/R Computer Drive User Manual


 
6.Command Specification RECEIVE DIAGNOSTIC RESULTS
SONY AIT-5 drive SDX-1100V series Ver.1.0
6-76
Table 6-81: RECEIVE DIAGNOSTICS results data
Bit
Byte
7 6 5 4 3 2 1 0
0 Reset
Error
Time
Re-Sync
(0)
Reserved Error Set
1 Error Code
2 Result A
3 Result B
4 Test Number
Reset error: This bit is set when an error occurs during power-on self-test.
Time Re-Sync: This bit indicates that the time stamp saved with the error log has no relation to that of the
previous entry. It is only set by the logging routine within the data buffer as an error is logged. This field is not
supported.
Error set: Various set of error codes exist. The definition of the error is dependent upon when set is taken from as
follows:
0 - Runtime errors
1 - Drive mechanism diagnostic errors
2 - Drive electronics diagnostic errors
Error code: Error codes for each error set are defined in the Diagnostics clause.
Result A and B: The content of these bytes depends on the test being run. See the Diagnostics clause.
Test number: This is the test number to which the message applies (if a test fails within a sequence, the individual
test number will be returned).