Sony SDX-1100V/R Computer Drive User Manual


 
7.Drive Diagnostics
7-4 SONY AIT-5 drive SDX-1100V series Ver.1.0
Sequence Test
00 Reset Sequence (61, 62, 71,72, 30) H
Main Processor Kernel Test
61 Main Processor ROM checksum P
62 Main Processor Destructive RAM Test P
Drive Test
71 Buffer RAM Test PH
72 DMA Test PH
7.2.5. RECEIVE DIAGNOSTIC RESULT command
Whenever a diagnostic test is executed, the drive automatically prepares a diagnostic test result that can be
returned to the host computer when a RECEIVE DIAGNOSTIC RESULT command is issued.
If the PF bit in the SEND DIAGNOSTIC command was sent to one, the diagnostic test result will be preceded by a
four-byte header which will be of the form:
Table 7-3: RECEIVE DIAGNOSTIC RESULT - SCSI-2 Header
Bit
Byte
7 6 5 4 3 2 1 0
0 Page Code (81h)
1 Reserved
2 (MSB) Page Length (00 05h)
3 (LSB)
Regardless of the PF bit in the SEND DIAGNOSTIC command, the five bytes of diagnostic test result information
will be of the form:
Table 7-4: RECEIVE DIAGNOSTIC RESULT
Bit
Byte
7 6 5 4 3 2 1 0
0 Reset
Error
Time
Re-Sync
Reserved Error Set
1 Error Code
2 Result A
3 Result B
4 Diagnostic Test Number
Reset error: This bit is set when an error occurs during power-on self-test.
Time Re-Sync: This bit indicates that the time stamp saved with the error log has no relation to that of the
previous entry. It is only set by the logging routine within the data buffer as an error is logged.