SpectraLink 1738EX Computer Hardware User Manual


 
SPECTRA SERIES 9
2.3 AC POWER
Do not use any switch-controlled outlets to power the transformer. Connect the transformer as shown in Figure 2.1
on page 7. Use Table 1 to determine the required transformer.
2.4 BACKUP BATTERY
In order to provide power during a power loss, connect a 12VDC 4Ah rechargeable acid/lead or gel cell backup
battery as shown in Figure 2.1 on page 7. Use a 7Ah battery to comply with UL fire requirements. Connect the
backup battery after applying AC power. When installing verify proper polarity as reversed connections will blow the
battery fuse. Also, refer to Battery Charge Current on page 43.
2.4.1 BATTERY TEST
If the battery is disconnected or if the battery fuse is blown, a No/Low Battery failure will appear in the
keypads’ Trouble Display (see page 50). This trouble will also appear if the battery’s capacity is too low or
if the voltage drops to 10.5 volts or lower while the control panel is running on the backup battery. At 8.5
volts or lower, the panel shuts down and all outputs close.
2.5 AUXILIARY POWER TERMINALS
The auxiliary power supply terminals can be used to power motion detectors, keypads and other modules or
accessories in the security system. A fuseless circuit protects the power supply against current overload and
automatically shuts down if the current exceeds 1.1A. If this occurs, the Maximum Auxiliary Current failure will
appear in the keypads’ Trouble Display (see page 50). Therefore, the combined current consumption of devices
connected to the auxiliary power supply should not exceed 700mA. If the auxiliary output is overloaded and is shut
down, you must disconnect all loads from the output for at least 10 seconds before reconnecting any load back to
the auxiliary output.
Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and Digiplex. Modules
with the APR3- prefix are compatible with Spectra( versions 2.0 and higher), Digiplex and DigiplexNE.
Table 1:
Transformer Requirements Table
Transformer: Amseco XP-1620 16VAC 20VA
(Not verified by UL)
UL: Basler Electric BE156240CAA007
16.5VAC 40VA
Spectra DC Power Supply rated at: 1.2A 1.5A
Auxiliary Supply can provide a maximum of: typ: 600mA, max: 700mA typ: 600mA, max: 700mA
Acceptable Battery Charge Currents 350mA 350mA/700mA
Table 2:
Current Consumption Table
Modules Current Consumption
Typical Maximum
Spectra 1686H and 1686V 10-Zone LED Keypad 62mA 116mA
Spectra 1689 16-Zone LED Keypad 50mA 117mA
Spectra 1641 LCD Keypad 60mA 80mA
Wireless Expansion Bus Module (SPC-319) 70mA 70mA
8-Zone Hardwire Bus Modules (APR3-ZX8) 30mA 30mA
4-PGM Output Bus Module (APR3-PGM4) 13mA 150mA
Printer Bus Module (APR3-PRT1) 22mA 40mA
4-Zone Expansion Bus Module (SPC-ZX4) 12mA 12mA
InTouch Voice-Assisted Arm/Disarm Bus Module (APR3-ADM2) 70mA 105mA
Motion Detectors (see detector instructions for details) 10 to 50mA