SPECTRA SERIES 47
[7] OFF / [8] ON: Trouble Only
When a tamper occurs on a wireless transmitter zone in a disarmed system, a Wireless Transmitter Supervision
Loss will appear in the keypads’ Trouble Display (see page 50) and the control panel will attempt to transmit the TX
Supervision Loss report code programmed in section [213]. When it occurs on in an armed system, the control
panel will follow the zone's Alarm Types setting (see page 24).
[7] ON / [8] OFF: Silent Alarm
When a tamper occurs on a wireless transmitter zone in a disarmed system, it functions the same as the Trouble
Only setting, but it will also generate a silent alarm. A silent alarm will not trigger any bells or sirens, but the system
will have to be disarmed. In an armed system, the control panel will follow the zone's Alarm Types setting (see
page 24).
[7] ON / [8] ON: Audible Alarm
When a tamper occurs on a wireless transmitter zone in a disarmed system, it functions the same as the Trouble
Only setting, except it will also generate an audible alarm. In an armed system, the control panel will follow the
zone's Alarm Types setting (see page 24).
10.17.1 RESTRICT ARMING ON SUPERVISION LOSS
Section [131]: Arming/Disarming Options
Option [6] OFF = Disabled (default)
Option [6] ON = Restrict Arming on Wireless Transmitter Supervision Loss
The control panel will not allow users to arm the system if it receives a Supervision Loss signal. Please
note that the Wireless Transmitter Supervision Options (see section 10.17) must be enabled. The control
panel will not arm any partition until all Supervision Loss trouble conditions are rectified.
10.17.2 SUPERVISION BYPASS OPTIONS
Section [131]: Arming/Disarming Options
Option [7] OFF = Generate Supervision Loss if detected on a Bypassed Wireless Transmitter Zone
(default)
Option [7] ON = No Supervision Loss if Detected on a Bypassed Wireless Transmitter Zone
When this feature is enabled, the Wireless Transmitter Supervision Options will follow the zone's bypass
definition. This means the control panel will not perform any action if a Supervision Loss occurs on a
bypassed zone. When this feature is disabled, the Wireless Transmitter Supervision Options will ignore the
bypass definition. This means the control panel will generate an incident as per Wireless Transmitter
Supervision Options if a supervision loss occurs on a bypassed zone.
10.18 REPROGRAM ALL EXPANSION MODULES
Section [750]
After removing an expansion bus module from the communication bus, the control panel keeps the module’s
programmed sections in memory. Therefore, if you add or replace a module or when you have downloaded the
contents of the Paradox Memory Key (see section 3.4), you can reprogram the modules with the settings saved in
the control panel. To do so, enter section [750] and press [
ENTER]. The keypad will emit 2 beeps every second while
downloading.