SSI America ERP2U Power Supply User Manual


 
SSI
ERP2U Power Supply Design Guide, V2.31
- 2 -
Revision History
Orig./Rev. Description of Changes
2.0
Post design guide
2.2
Added higher power levels up to 800W.
Added 350mm depth.
Removed lower power levels.
Added standby fan operation.
Added option for tighter 12V regulation.
Added 12V4.
Add new SSI efficiency requirements (recommended level & loading conditions).
Reduced holdup time requirements to 75% of max load.
Increase 12V rails for >650W.
Tpwok_on max time reduced to 500msec.
Change 5VSB to 3.0A for >650W.
Added reference to PSMI spec.
Modified SMBus section (FRU and PSMI) to 3.3V with 5V tolerance.
Modified 240VA section; removed common plane, change to <20A for all 12V outputs.
Updated sound power & airflow requirements
Remove reference to split and common rails
Updated efficiency testing method
2.3
Increase 5V current to 30A and combined 3.3V/5V power to 160W for the 700-800W power levels.
Increase 12V1/2 current for 550W-650W power levels. Relax require regulation limits. Added
optional regulation limits.
2.31
Fixed error in 3.3V and 5V loading. Increased 3.3V/5V combined power.