4. Peak power and current loading shall be supported for a minimum of 10 second.
5. Maximum combined current for the 12 V outputs shall be 45 A.
6. Maximum 12V combined peak current shall be 54 A.
7. The 3.3V and 5V may be supply by the module or DC/DC converters powered from +12V in the cage.
Table 16: 700 W Load Ratings
Voltage Minimum Continuous Maximum Continuous Peak
+3.3 V
7
0.8 A 24 A
+5 V
7
0.5 A 30 A
+12V1 0 A 16 A 18 A
+12V2 0 A 16 A 18 A
+12V3 0.9 A 16 A 18 A
+12V4 0.1 A 16 A 18 A
-12 V 0 A 0.5 A
+5 VSB 0.1 A 3.0 A 3.5 A
1. Maximum continuous total DC output power should not exceed 700 W.
2. Maximum continuous combined load on +3.3 VDC and +5 VDC outputs shall not exceed 170 W.
3. Maximum Peak total DC output power should not exceed 780 W.
4. Peak power and current loading shall be supported for a minimum of 10 second.
5. Maximum combined current for the 12 V outputs shall be 56 A.
6. Maximum 12V combined peak current shall be 62 A.
7. The 3.3V and 5V may be supply by the module or DC/DC converters powered from +12V in the cage.
Table 17: 750 W Load Ratings
Voltage Minimum Continuous Maximum Continuous Peak
+3.3 V
7
0.8 A 24 A
+5 V
7
0.5 A 30 A
+12V1 0 A 16 A 18 A
+12V2 0 A 16 A 18 A
+12V3 0.9 A 16 A 18 A
+12V4 0.1 A 16 A 18 A
-12 V 0 A 0.5 A
+5 VSB 0.1 A 3.0 A 3.5 A
1. Maximum continuous total DC output power should not exceed 750 W.
2. Maximum continuous combined load on +3.3 VDC and +5 VDC outputs shall not exceed 170 W.
3. Maximum Peak total DC output power should not exceed 830 W.
4. Peak power and current loading shall be supported for a minimum of 10 second.
5. Maximum combined current for the 12 V outputs shall be 60 A.
6. Maximum 12V combined peak current shall be 66 A.
7. The 3.3V and 5V may be supply by the module or DC/DC converters powered from +12V in the cage.