Known Issues and Bugs
The following HBA issues exist at this time.
■ CR 6266132. Booting from the Sun StorEdge 3500 family array fails with the single
and dual port HBAs in certain configurations.
Workaround: None; booting from a Sun StorEdge 3500 family array is not
supported at this time.
■ CR 6350753. Packet timeout. (chip abort: sbp=600064a1e10 iotag=0. Completing.)
Workaround: None at this time. A fix is targeted for the Sun StorEdge SAN
Foundation Software release 4.4.10 for Sun Solaris OS 8 and 9 SPARC, patches
120222-10 (S10_SPARC), and 120223-10 (S10_x86).
■ CR 6367185. Performing I/O operations on HBA ports 0 and 1 intermittently
stops when using Emulex 10k cards with the Sun StorEdge 3500 family arrays.
Workaround: None at this time. A fix is being investigated.
■ CR 6313136. A Sun StorEdge 3510 FC Array 0x47 SCSI parity error occurs when
the Emulex HBA is connected to Sun StorEdge 3510 JBOD FC Array
.