Chapter 3 Hardware Installation 21
▼ To Verify the Attached Storage
● If online storage is connected to the HBA installed in a SPARC system, use the
apply show-children command to list the attached storage.
In the example that follows, a storage JBOD has twelve targets attached to one port
of the dual-ported HBA.
Note – You may need to use the reset-all command before entering apply
show-children.
TABLE 3-4
{0} ok apply show-children /pci@7c0/pci@0/pci@9/SUNW,emlxs@0
Device ALPA b6 WWPN 215000c0ff00223d
LUN 0 ESI Device SUN StorEdge 3510F D1046
Link attention
Device ALPA b9 WWPN 2100000c50c30555
LUN 0 Disk SEAGATE ST3146807FC 0006
Device ALPA ba WWPN 2100000c50c30525
LUN 0 Disk SEAGATE ST3146807FC 0006
Device ALPA bc WWPN 500000e010172831
LUN 0 Disk FUJITSU MAP3147F SUN146G0301
Device ALPA c3 WWPN 2100000c50c3051b
LUN 0 Disk SEAGATE ST3146807FC 0006
Device ALPA c5 WWPN 2100000c50c30567
LUN 0 Disk SEAGATE ST3146807FC 0006
Device ALPA c6 WWPN 500000e0101727d1
LUN 0 Disk FUJITSU MAP3147F SUN146G0301
Device ALPA c7 WWPN 21000004cf64f1db
LUN 0 Disk SEAGATE ST336752FSUN36G 0508
Device ALPA c9 WWPN 2100000c50c30513
LUN 0 Disk SEAGATE ST3146807FC 0006
Device ALPA ca WWPN 500000e0101727b1
LUN 0 Disk FUJITSU MAP3147F SUN146G0301
Device ALPA cb WWPN 2100000c50c3050e
LUN 0 Disk SEAGATE ST3146807FC 0006
Device ALPA cc WWPN 21000004cf64dc04
LUN 0 Disk SEAGATE ST336752FSUN36G 0508
Device ALPA cd WWPN 21000004cf5728c0
LUN 0 Disk SEAGATE ST373307FSUN72G 0407
{0} ok