Chapter 2 Supported System Configurations 11
■ CR 6381138. Sun StorEdge 3511 and 3510 Arrays can experience a SCSI transport
failure for a’timeout’ reason.
Workaround: None at this time. A fix is being investigated.
■ CR 6352189. OBP probe gives unexpected output for unmapped channel / Sun
StorEdge 3500 family arrays. This only occurs on the first probe-SCSI-all after a
reset.
Workaround: Perform another probe-scsi-all after a reset. The second try will
yield correct results.
A fix will be made available in the next FCode release after version 1.50a8.
■ CR 6306640. Enabling the BIOS of the “LP10000” card causes the system to fail to
boot. Enabling the HBA BIOS hangs up all boot processes.
Workaround: None at this time. A fix is currently under investigation.
Disable the single or dual port HBA BIOS (default setting) and boot from the
system disk, or other supported boot device.