Sun Microsystems PCI-X Computer Hardware User Manual


 
Chapter 2 Supported System Configurations 11
CR 6381138. Sun StorEdge 3511 and 3510 Arrays can experience a SCSI transport
failure for a’timeout’ reason.
Workaround: None at this time. A fix is being investigated.
CR 6352189. OBP probe gives unexpected output for unmapped channel / Sun
StorEdge 3500 family arrays. This only occurs on the first probe-SCSI-all after a
reset.
Workaround: Perform another probe-scsi-all after a reset. The second try will
yield correct results.
A fix will be made available in the next FCode release after version 1.50a8.
CR 6306640. Enabling the BIOS of the “LP10000” card causes the system to fail to
boot. Enabling the HBA BIOS hangs up all boot processes.
Workaround: None at this time. A fix is currently under investigation.
Disable the single or dual port HBA BIOS (default setting) and boot from the
system disk, or other supported boot device.