Sun Microsystems PCI-X Computer Hardware User Manual


 
18 Sun StorageTek Enterprise PCI-X 4 Gb FC Single & Dual Port Emulex HBAInstallation & Interop Guide January 2007
To Apply Power
1. Verify that the HBA is securely installed in the system.
2. Verify that the correct optical cable is attached.
3. Plug in and power on the system.
4. Observe the status of light-emitting diodes (LEDs) for the power-on self-test
(POST) results as shown in
TABLE 3-2.
TABLE 3-2 summarizes LED indicator combinations. The LEDs can be seen
through the openings in the HBA’s mounting bracket. Each port has a
corresponding set of LEDs that provide a visual indication of the operating state.
The slow blink rate is 1 Hz; the fast blink rate is 4 Hz; the flashing state is an
irregular on/off appearance reflecting program activity. For the Link Rate,
between each group of fast blinks (1, 2, or 3), there is a 1-Hz pause when the LED
is off. You should observe the LED sequence for several seconds to ensure that
the pause is correctly identified.
TABLE 3-2 LED Indicator Status Definitions
Green LED Yellow LED State
Off Off Wake Up Failure (Dead Board)
Off On POST Failure (Dead Board)
Off Slow Blink Wake-Up Failure Monitor
Off Fast Blink Failure in POST
Off Flashing POST Processing in Progress
On Off Failure While Functioning
On On Failure While Functioning
On 1 Fast Blink 1-Gb Link Rate
Normal, link up
On 2 Fast Blink 2-Gb Link Rate
Normal, link up
On 3 Fast Blink 4-Gb Link Rate
Normal, link up
Slow Blink Off Normal - Link Down
Slow Blink On Not defined
Slow Blink Slow Blink Offline for Download
Slow Blink Fast Blink Restricted Offline Mode
(Waiting for Restart)