SUPER MICRO Computer 7047A-T Switch User Manual


 
6-4
SuperWorkstation 7047A-73/7047A-T User's Manual
6-3 System Fans
Two 8-cm PWM chassis fans provide air intake while one 9-cm PWM exhaust fan
expels hot air from the chassis. All are low-noise fans that result in "Whisper-Quiet"
operation (~28 dB). The fans should be connected to headers on the serverboard
(see Chapter 5).
The power supply includes redundant cooling fans. If one fan fails, the remaining
fan will ramp up its rpm to provide suf cient cooling. The Power Fail LED will il-
luminate and an audible alarm will sound, which can be silenced with a button on
the power supply. If a power supply fan fails, you should replace the power supply
at your earliest convenience.
Fan Failure
Under normal operation, the chassis fans, the exhaust fan and the power supply
fans run continuously. The chassis fans are hot-pluggable and can be replaced
without powering down the system.
Replacing Chassis Cooling Fans
Removing a Fan
1. First locate the failed chassis fan by removing the top/left chassis cover (see
Chapter 2 for details). Locate the fan that has stopped working.
2. Depress the locking tab on the failed fan: on a chassis fan, push the tab on
the side of the housing inward, on the exhaust fan push down on the colored
tab.
3. With the tab depressed, pull the unit straight out (see Figure 6-3). The wiring
for these fans has been designed to detach automatically.
Installing a New Fan
1. Replace the failed fan with an identical one (available from Supermicro)
2. Install it in the same position and orientation as the one you removed; it
should click into place when fully inserted.
3. Check that the fan is working then replace the top/left side chassis panel.