Symbol Technologies P370 Scanner User Manual


 
5-97
Parameter Menus
Scanner Address
Scan the following barcode, followed by 3 digits from the numeric barcode section (starting
on page 5-101), to set the address of the scanner (scanner ID).
The number of scanner addresses (scanner IDs) varies with the selected communication
protocol.
RS-232/Synapse range from 001 to 254
MCL Link Lite (MCL Net) range from 001 to 002
MCL Link (MCL Net) range from 001 to 254
SCANNER ADDRESS
MCL-Net Transmit Retries
Scan the following barcode, followed by 2 digits from the numeric barcode section (starting
on page 5-101), to define the number of retries in the range 1 to 10.
MCL-NET RETRIES
MCL-Net Frame Timeout
Scan the following barcode, followed by 2 digits from the numeric barcode section (starting
on page 5-101), to define the amount of time to wait for an ACK or NAK from the host before
retransmitting. The timeout is in 100 ms increments in the range 100 ms to 3000 ms.