Symbol Technologies P370 Scanner User Manual


 
4-4
P470/370 RF Scanner Product Reference Guide
Technical Specifications
Table 4-2. Technical Specification s
Item Description
Decode Capability The RF scanner can be programmed to decode the following
code types: UPC/EAN, Bookland EAN, Code 11, Code 39,
Code 39 Full ASCII, Trioptic Code 39, Code 93, Codabar,
Interleaved 2 of 5, Code 128, EAN 128, Discrete 2 of 5, MSI
Plessey, and Coupon Code.
The RF scanner can auto-discriminate between all of the above
code types except for Code 39 and Code 39 Full ASCII.
Scanner Beeper Operation User-selectable: Enabled, Disabled.
Scan Repetition Rate 35 (± 5) scans/sec (bidirectional)
Roll (Skew) Tolerance ± 30° from normal
Pitch ± 65° from normal
Yaw ± 60° from normal
Decode Depth of Field See Decode Zone on page 3-24.
Print Contrast Minimum 20% absolute dark/light differential, measured at the wavelength
of the laser diode.
Ambient Light Immunity
Artificial Lighting 450 ft. candles 4844 lux
Sunlight 10,000 ft. candles 107,640 lux
Operating Temperature
P370 (Industrial)
P470 (Retail)
-4° to 122°F-20° to 50°C
32° to 104°F0° to 40°C
Storage Temperature -40° to 140°F-40° to 60°C
Sealing P370: All components sealed to IP 54 specification against
wind blown dust and rain.
Humidity 5% to 95% (non-condensing)
Durability (Scanner)
P370 (Industrial)
P470 (Retail)
P370: 6-ft. (1.8 m)
P470: 5-ft. (1.5 m)
Drops to concrete over entire temperature range