Symbol Technologies P370 Scanner User Manual


 
A-5
Bar Code Information
Codabar 0 No check digit processing.
1 Reader has checked check digit.
3 Reader has stripped check digit before transmission.
Example: A Codabar bar code without check digit, 4123, is transmitted as
]F04123
Code 93 0 No options specified at this time. Always transmit 0.
Example: A Code 93 bar code 012345678905 is transmitted as
]G0012345678905
MSI Plessey 0 Single check digit checked.
1 Two check digits checked.
2 Single check digit verified and stripped before
transmission.
3 Two check digits verified and stripped before
transmission.
Example: An MSI Plessey bar code 4123, with a single check digit
checked, is transmitted as ]M04123
D 2 of 5 0 No options specified at this time. Always transmit 0.
Example: A D 2 of 5 bar code 4123, is transmitted as ]S04123
UPC/EAN 0 Standard packet in full EAN country code format, which
is 13 digits for UPC-A and UPC-E (not including
supplemental data).
1 Two-digit supplement data only.
2 Five-digit supplement data only.
4 EAN-8 data packet.
Example: A UPC-A bar code 012345678905 is transmitted as
]E00012345678905
Bookland EAN 0 No options specified at this time. Always transmit 0.
Example: A Bookland EAN bar code 123456789X is transmitted as
]X0123456789X
Table A-3. Modifier Characters (Continued)
Code Type Option Value Option