TANDBERG 3G Gateway Data port Command Interface User Guide
OPC: <0 .. 16383>
NetworkIndicator: <International0/International1/National0/National1>
Law: <ALaw/ULaw>
LinkSet [1 .. 2] Mode: <On/Off>
LinkSet [1 .. 2] DPC: <0 .. 16383>
LinkSet [1 .. 2] Link [1 .. 2] Mode: <On/Off>
LinkSet [1 .. 2] Link [1 .. 2] Trunk: <1 .. 4>
LinkSet [1 .. 2] Link [1 .. 2] Timeslot: <1 .. 31>
LinkSet [1 .. 2] Link [1 .. 2] SLC: <0 .. 15>
Trunk [1 .. 4] Mode: <On/Off>
Trunk [1 .. 4] DPC: <0 .. 16383>
Trunk [1 .. 4] CircuitIdentificationCode: <0 .. 16383>
Route [1 .. 8] DPC: <0 .. 16383>
Route [1 .. 8] Priority: <1 .. 4>
Route [1 .. 8] LinkSet: <Off/1/2>
---
sub-commands:
• OPC: A number between 0-2
14
, which uniquely identifies a signaling point, in this case the
3G Gateway, within a telephone network. This number consists of three parts, i.e. a network,
cluster and member number, and will be provided by the network operator.
• NetworkIndicator:,A two bit data field within the Service Information Octet of the
Message Signal Unit that permits discrimination between national and international
messages.
• Law: audio standard: Either ALAW or ULAW. An a-law algorithm is a standard
companding, i.e. compressing and expanding, algorithm, used in European digital
communication systems to optimize, i.e. modify, the dynamic range of an analog signal for
digitizing. The µ-law algorithm is similar to a-law and used in North American and Japanese
systems.
• LinkSet Mode: Enable or disable linksets.
• LinkSet DPC: Uniquely identifies the destination signaling point of the link. This can differ
from the DPC of the trunk, e.g. the DPC of a Signaling Transfer Point (STP), see example 2
below.
• LinkSet Link Mode: Enable a link in a link set.
• LinkSet Link Trunk: Number of the trunk (1 - 4) in which a time slot is reserved for
signaling.
• LinkSet Link Timeslot: Number of the time slot, within aforementioned trunk, reserved for
signaling.
• LinkSet Link SLC: A Signaling Link Code is a unique link number provided by the
network operator to identify a link.
• Trunk Mode: Enable or disable a trunk.
• Trunk DPC: Uniquely identifies the destination signaling point of the trunk. It will be
provided by the network operator.
D1320203 21