TANDBERG 3G Gateway Data port Command Interface User Guide
• Trunk CircuitIdentificationCode: The Circuit Identification Code is a unique identifier for
a data time slot in a cable (trunk). In this case the CIC acts as base address and can be
defined for each SS7 trunk and sets the first time-slot number of the respective SS7 trunk.
• Route DPC: Unique identifier indicating the destination signaling point of a trunk.
• Route Priority: Priority level of the route to the destination signaling point. Fail-over
signaling paths will be followed according to this priority.
• Route LinkSet: Indicates the link to the destination signaling point according to the above
mentioned priority setting.
For more details on the sub-commands please read the chapter about SS7 in the 3G Gateway
User Manual.
Example of SS7 feedback:
*c xConfiguration SS7 OPC: 0
*c xConfiguration SS7 NetworkIndicator: National0
*c xConfiguration SS7 Law: ALaw
*c xConfiguration SS7 LinkSet 1 Mode: Off
*c xConfiguration SS7 LinkSet 1 DPC: 0
*c xConfiguration SS7 LinkSet 1 Link 1 Mode: Off
*c xConfiguration SS7 LinkSet 1 Link 1 Trunk: 0
*c xConfiguration SS7 LinkSet 1 Link 1 Timeslot: 0
*c xConfiguration SS7 LinkSet 1 Link 1 SLC: 0
*c xConfiguration SS7 LinkSet 1 Link 2 Mode: Off
*c xConfiguration SS7 LinkSet 1 Link 2 Trunk: 0
*c xConfiguration SS7 LinkSet 1 Link 2 Timeslot: 0
*c xConfiguration SS7 LinkSet 1 Link 2 SLC: 0
*c xConfiguration SS7 LinkSet 2 Mode: Off
*c xConfiguration SS7 LinkSet 2 DPC: 0
*c xConfiguration SS7 LinkSet 2 Link 1 Mode: Off
*c xConfiguration SS7 LinkSet 2 Link 1 Trunk: 0
*c xConfiguration SS7 LinkSet 2 Link 1 Timeslot: 0
*c xConfiguration SS7 LinkSet 2 Link 1 SLC: 0
*c xConfiguration SS7 LinkSet 2 Link 2 Mode: Off
*c xConfiguration SS7 LinkSet 2 Link 2 Trunk: 0
*c xConfiguration SS7 LinkSet 2 Link 2 Timeslot: 0
*c xConfiguration SS7 LinkSet 2 Link 2 SLC: 0
D1320203 22