Tascam MX-2424 Computer Drive User Manual


 
- 14 -
MX-2424 2.0 and Viewnet 2.0 Release Notes
96k/88.2k high sample rate recording on 12 tracks
Support for HFS+ Volumes
Miscellaneous Enhancements
Miscellaneous Software Maintenance
Miscellaneous Notes
Remember to update to Viewnet 2.0 when updating to MX-OS Version 2.0.
96k/88.2k High Sample Rate Recording on 12 Tracks
With version 2.0, the MX-2424 can now record and play at sample rates of 88.2kHz, 96kHz, as well as
their associated pull-up and pull-down rates.
When operating at high sample rates, all activity takes place on tracks 1 through 12.
There are several new menus that incorporate the new high sample rate features:
Menu 005: Sample Rate
Sample rate options have been added for 88112, 88200, 88288, 95904, 96000, and 96096. When
selecting any of these sample rates, the “2X” LED will illuminate on the front panel of the MX-
2424.
e.
This light combines with the "base" sample rate setting to indicate the operating sample rat
or example, if the 48k and the 2x lights are both lit, the MX-2424 is set to record at 96k.
F
NOTE: Whenever the MX-2424 is switched between a sample rate in the base ("1X") range and
one of the high sample rates in the ("2X") range, it will mute all of its audio outputs for the
duration of the switchover. If the Analog I/O option is installed, the Analog input converters are
reset during the rate switch, and are automatically re-calibrated when the switchover has
completed. The entire process may take up to ¾ of a second.